Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0223-00435
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Back shear wall hold down over spalled. All shear wall anchor bolts must have 3”x3” plate washer. Anchor bolts must be placed within inner third of sill plate. Fix cripple under window by porch. | |
08/10/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |