Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141431650


Addresses:

7742 S VIA PERFECTA


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0223-00435

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/08/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Back shear wall hold down over spalled. All shear wall anchor bolts must have 3”x3” plate washer. Anchor bolts must be placed within inner third of sill plate. Fix cripple under window by porch.
08/10/2023 COT - RSBU - Exterior Clips/Sheathing  Passed