| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 04/08/2026 Partial pass pending underground circuit to connect kitchen island outlets. Add Boca plate to DWV vent on top plate in front bathroom. |
|
| 04/14/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 04/14/2026 Partial for engineer fix/letter required on 1" deep trenching into post-tensioned slab from kitchen island to wall to accommodate electrical conduit for outlets. |
|
| 04/21/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 04/21/2026 Engineer letter received, verified conduit to kitchen island in slab. Okay to proceed. |