Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0126-00024

Parcel: 14101013E


Addresses:

10017 E LEBARON DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
03/20/2026 COT - RSBU - Roof Nailing  Re-inspection required 3/20/2026
Add anchor bolts at marked locations, add nails to over-penetrated shear wall SW9 at front bedroom as marked, add anchor bolt and steel washer plate to SW11 at sill plate edge as marked, damaged A2 truss as marked at garage requires engineer fix. STOPPED INSPECTION, MORE ITEMS MAY BE PRESENT.
03/23/2026 COT - RSBU - Roof Nailing  Partial Pass Partial pass pending truss repair
03/27/2026 COT - RSBU - Roof Nailing  Passed 3.27.26
Truss report on site proceed