Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/03/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
9-3-26 provide (12)16 D nails at top plate splices at marked locations * add anchor bolt at Marked locations* all window openings upstairs are required to have 216 D nails 8 inches on center throughout* belly band requires 3 inches on center throughout please re-walk before calling inspection back in. |
| 09/08/2026 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |