Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/03/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9-3-26 provide (12)16 D nails at top plate splices at marked locations * add anchor bolt at Marked locations* all window openings upstairs are required to have 216 D nails 8 inches on center throughout* belly band requires 3 inches on center throughout please re-walk before calling inspection back in.
09/08/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9-8-26 all items have been corrected. OK to proceed