Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0126-00015
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 03/03/2026 Missing steel washer plates on SW11 and SW 13, add anchor bolts at marked locations, add cs16 strap to rear patio beam to post. Rear patio on SE side needs fix: SW11 requires not to cut into for pocket beam, requires HUC26-2 hanger instead. NOTE: stopped inspection, upstairs needs to be walked. |
|
| 03/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 03/04/2026 Corrections made to prior inspection. Verified added nails to loose panel and h2.5 at west wall truss to top plate. |