Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
Permit Number - TC-MDP-0125-00059
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2025 | COT - RSME - Mechanical Final | Re-inspection required | 8.18.2025 Needs non-metallic plumbing labeled on dead front, fill receptacle box area near main panel, missing post-tension tag, missing metal cap for clean out in driveway, main breaker panel shows AC breaker at 50A but max on label shows 40A, insulate exposed copper in garage, add receptacle on west wall next to future refrigerator, clean outs near AC need cut to grade, clamp whip midway on AC, heat kit in attic needs marked. |
|
| 09/05/2025 | COT - RSME - Mechanical Final | Re-inspection required | 9/4/25 1. Heat strips need labeled on AHU 2. Whip for a/c needs clamp midway 3. Max fuse on condenser is 40A breaker. 4. Box near main panel still needs to be sealed. |
|
| 09/16/2025 | COT - RSME - Mechanical Final | Passed | Passed final 9/16/25 |