Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSEL - Grounding/Bonding
Permit Number - TC-MDP-0125-00041
Inspection Description - COT - RSEL - Grounding/Bonding
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2025 | COT - RSEL - Grounding/Bonding | Partial Pass | 5/13/25 Partial pass. UFER. |
|
| 06/18/2025 | COT - RSEL - Grounding/Bonding | Re-inspection required | 6/18/25: Dryer duct must be sealed at all joints, all penetrations shall be sealed through top plate and vapor barrier, flex duct supports required throughout, plumbing lines not complete, DWV not under test, tub not under test, nail plates required where plumbing/mechanical/electrical come within 1 1/4" of face of 2x. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. ONLY WALKED WEST UNIT DUE TO WORKERS STILL ROUGHING-IN PLUMBING LINES. | |
| 06/20/2025 | COT - RSEL - Grounding/Bonding | Passed |