Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0125-00005
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 4/29/25: Roof sheathing must be properly fastened at bedroom, straps at beam to post connection must be fastened per plan, shear wall fasteners not per plan, fasteners must be 3/8" from edge , MASA clips must have 7 nail minimum to suffice for a 1/2" anchor bolt | |
| 05/01/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/29/25: Roof sheathing must be properly fastened at bedroom, straps at beam to post connection must be fastened per plan, shear wall fasteners not per plan, fasteners must be 3/8" from edge , MASA clips must have 7 nail minimum to suffice for a 1/2" anchor bolt 5/1/25: (4) MASA CLIPS MISSING MARKED ON SILL PLATE, (2) at back porch S.G.D and (2) at entry. Verify at intermediate inspection |