Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0125-00005

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
04/29/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4/29/25: Roof sheathing must be properly fastened at bedroom, straps at beam to post connection must be fastened per plan, shear wall fasteners not per plan, fasteners must be 3/8" from edge , MASA clips must have 7 nail minimum to suffice for a 1/2" anchor bolt
05/01/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/29/25: Roof sheathing must be properly fastened at bedroom, straps at beam to post connection must be fastened per plan, shear wall fasteners not per plan, fasteners must be 3/8" from edge , MASA clips must have 7 nail minimum to suffice for a 1/2" anchor bolt
5/1/25: (4) MASA CLIPS MISSING MARKED ON SILL PLATE, (2) at back porch S.G.D and (2) at entry. Verify at intermediate inspection