Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0124-00155
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/26/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x4 studs throughout in garage for girder trusses and posts above, missing 2-2x4 studs at each end for 2-2x8 header between foyer and dining room, missing 2-2x4 for girder truss at dining room, beam to posts not per S5.1 #6, missing second 2x6 stud at exterior by stairs to support GT, blocking between trusses loose not nailed off, roof nailing missing throughout left side of house, rsp4 clips needed at back of house, truss A04 missing proper lateral bracing. | |
05/02/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Not ready. | |
05/06/2024 | COT - RSBU - Roof Nailing | Re-inspection required | ||
05/08/2024 | COT - RSBU - Roof Nailing | Passed |