Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141435420


Addresses:

6712 E VIA DE AYATE


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0124-00128

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/10/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add shims at gaps between top plate and bottom chord of truss at all middle bearing points with nailed H2.5 clips, missing anchor bolts and shot pins throughout, add toe nailing to stud at laundry.
05/13/2024 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Missing toe nailing from stud to sole plate at laundry. Marked on sole plate. Correction can be seen at intermediate. Partial-pass. Ok to proceed.
06/21/2024 COT - RSBU - Exterior Clips/Sheathing  Passed