Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0124-00128

Parcel: 141435420


Addresses:

6712 E VIA DE AYATE

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/10/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Add shims at gaps between top plate and bottom chord of truss at all middle bearing points with nailed H2.5 clips, missing anchor bolts and shot pins throughout, add toe nailing to stud at laundry.
05/13/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass Missing toe nailing from stud to sole plate at laundry. Marked on sole plate. Correction can be seen at intermediate. Partial-pass. Ok to proceed.
06/21/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed