Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0124-00127
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing 2-2x4s at 3 point bearing GT at front and back of house, missing second king stud at each end at nook window, truss to gable end girder truss missing hangers per SD1.3a detail 18 at front and back of house, front and back porch not fastened per SD1.3a detail 6, missing shot pins throughout, missing hold downs at shear walls, add nails to shear wall studs at garage shear wall, add anchor bolts left side of house. | |
05/09/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Still missing 2-2x4s at point bearing GT at front and back of house, missing second king stud at each end at nook window, truss to gable end girder truss missing hangers per SD1.3a detail 18 at front and back of house, missing shot pins. Stopped inspections. Make all corrections per last notes. | |
05/10/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required (with fee) | Re-inspection required. Workers still working on corrections. Missing 2-2x4s at 3 point bearing GT at back of house, missing 2-2x4 studs at each end of front of garage for GT, missing second king stud at each end at nook window, front and back porch not fastened per SD1.3a detail 6, missing hold downs at shear walls, add nails to shear wall studs at garage shear wall, add anchor bolts left side of house. | |
05/13/2024 | COT - RSBU - Exterior Clips/Sheathing | Partial Pass | 2-2x4 studs required at each end of garage to support GT per plans., still missing second king stud at nook and kitchen windows, 2-2x4 studs required for GT at wall between master W.I.C. and back porch per plans. Partial-pass. Corrections can be seen at Intermediate. Ok to proceed. | |
06/13/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Still missing 2-2x4 studs required at each end of garage to support GT per plans., 2-2x4 studs required for GT at wall between master W.I.C. and back porch per plans. | |
06/17/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |