Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Building Progress

Permit Number - TC-MDP-0124-00112

Inspection Description - COT - HCBU - Building Progress

Inspection Status - Partial Pass

Date Description Inspector Results Comments
01/24/2025 COT - HCBU - Building Progress Partial Pass Partial pass for bathroom ceilings and please remove pancake boxes and put in old work or some other box for the Daisy chain boxes at island area in kitchen and please tie up flex ducks on exhaust fans prior to installation of drywall
01/27/2025 COT - HCBU - Building Progress Not Ready
01/28/2025 COT - HCBU - Building Progress Not Ready
04/10/2024 COT - HCBU - Building Progress Partial Pass Partial pass. Footings on both east and west ends of the building for stairs approved. Okay for concrete placement. 4/10/2024
04/15/2024 COT - HCBU - Building Progress Partial Pass Partial pass. Stem walls for both east and west ends stairwell approved. Okay for concrete placement. 4/15/2024
07/15/2025 COT - HCBU - Building Progress Passed
10/25/2024 COT - HCBU - Building Progress Partial Pass Partial pass. 1st layer at all party walls throughout building fire taped and approved. Okay for 2nd layer. 10/25/2024
12/02/2024 COT - HCBU - Building Progress Partial Pass Partial for screw inspection ok for fire tape, do not install hard lids in soffit areas until fire tape inspection is completed