Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140363700


Addresses:

6452 S AMBARELLA DR


Inspection Status: Canceled

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0124-00111

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Canceled

Date Description Inspector Results Comments
07/03/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Canceled per contractor. 7/3/2024
07/11/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Canceled per contractor. 7/11/2024
07/12/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Loose shear walls throughout. Add anchor bolts per shear wall schedule, and at perimeter. Add nails at ledger back patio. Add shims to 3 point bearing trusses and cs16 straps due to over notching top plate. Add straps to header to stud at porch. 7/12/2023
07/23/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 7/23/2024