Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0124-00111
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Canceled | Canceled per contractor. 7/3/2024 | |
07/11/2024 | COT - RSBU - Exterior Clips/Sheathing | Canceled | Canceled per contractor. 7/11/2024 | |
07/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Loose shear walls throughout. Add anchor bolts per shear wall schedule, and at perimeter. Add nails at ledger back patio. Add shims to 3 point bearing trusses and cs16 straps due to over notching top plate. Add straps to header to stud at porch. 7/12/2023 | |
07/23/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections were made. 7/23/2024 |