Inspection Status: Canceled
Inspection History: COT - RSBU - Roof Nailing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/03/2024 |
COT - RSBU - Roof Nailing |
|
Canceled |
Canceled per contractor. 7/3/2024 |
| 07/11/2024 |
COT - RSBU - Roof Nailing |
|
Canceled |
Canceled per contractor. 7/11/2024 |
| 07/12/2024 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
Loose shear walls throughout. Add anchor bolts per shear wall schedule, and at perimeter. Add nails at ledger back patio. Add shims to 3 point bearing trusses and cs16 straps due to over notching top plate. Add straps to header to stud at porch. 7/12/2023 |
| 07/23/2024 |
COT - RSBU - Roof Nailing |
|
Passed |
Corrections were made. 7/23/2024 |