Permit: TC-MDP-0124-00111

Parcel: 140363700


Addresses:

6452 S AMBARELLA DR

Inspection Status: Canceled

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
07/03/2024 COT - RSBU - Roof Nailing  Canceled Canceled per contractor. 7/3/2024
07/11/2024 COT - RSBU - Roof Nailing  Canceled Canceled per contractor. 7/11/2024
07/12/2024 COT - RSBU - Roof Nailing  Re-inspection required Loose shear walls throughout. Add anchor bolts per shear wall schedule, and at perimeter. Add nails at ledger back patio. Add shims to 3 point bearing trusses and cs16 straps due to over notching top plate. Add straps to header to stud at porch. 7/12/2023
07/23/2024 COT - RSBU - Roof Nailing  Passed Corrections were made. 7/23/2024