Inspection Status: Canceled

Inspection History: RSBU - Building Final 

Permit Number - TC-MDP-0124-00110

Inspection Description - RSBU - Building Final 

Inspection Status - Canceled

Date Description Inspector Results Comments
09/20/2024 RSBU - Building Final  Canceled
10/02/2024 RSBU - Building Final  Re-inspection required 9-20-2024,contractor cancelled inspection and will reschedule when ready.
10/2/24: clean out at drive way required, main panel cover not properly fastened, Pressure relief valve must terminate 6" above grade. 3" clearance required from grade to A/C condenser, receptacles at back door have no power, light at back door entry has no power, properly support refrigerant lines in attic.
10/04/2024 RSBU - Building Final  Passed 10/4/2024 per previous notes.