Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0124-00050

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/25/2024 COT - RSBU - Roof Nailing  Re-inspection required Add toe nails or hangers at porch entry. Provide hangers at garage area. Add cripple studs underneath gable truss at porch area. Add cut nails to interior walls. Add anchor bolts at pop outs front entry. One anchor bolt at south wall. Add more nails to h25 above garage beam. 7/25/2024
08/02/2024 COT - RSBU - Roof Nailing  Passed Corrections were made. 8/2/2024