Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Interior Shear Bracing
Permit Number - TC-MDP-0124-00047
Inspection Description - COT - RSBU - Interior Shear Bracing
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2024 | COT - RSBU - Interior Shear Bracing | Canceled | Canceled by contractor 9/30/2024 | |
10/01/2024 | COT - RSBU - Interior Shear Bracing | Re-inspection required | Re inspection required. 10/1/2024 | |
10/02/2024 | COT - RSBU - Interior Shear Bracing | Not Ready | Canceled by contractor 9/30/2024 Re inspection required. 10/1/2024 10/2/24: fasteners not per schedule throughout, shearwalls missing at garage and kitchen, fasteners must be no less than 3/8" from edge and shall penetrate no more than 1/8". Throughout home . Not ready |
|
10/03/2024 | COT - RSBU - Interior Shear Bracing | Passed |