Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0124-00045
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/10/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is evenly spaced and secured to forms, underground electrical conduit is installed for kitchen island, underground plumbing pipes are properly wrapped with foam, shear wall hold downs are attached to form per plan location, masa clips are evenly spaced on forms, rebar reinforcement is installed per plans, and Ufer ground is installed in bottom of garage footing. Okay to pour concrete for footings and slab. |