Parcel: 133570590


Addresses:

455 N GRAY SLATE DR


Inspection Status: Passed

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0124-00045

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Passed

Date Description Inspector Results Comments
07/10/2024 COT - RSBU - Preslab   Passed Concrete forms are set, post tension cabling is evenly spaced and secured to forms, underground electrical conduit is installed for kitchen island, underground plumbing pipes are properly wrapped with foam, shear wall hold downs are attached to form per plan location, masa clips are evenly spaced on forms, rebar reinforcement is installed per plans, and Ufer ground is installed in bottom of garage footing. Okay to pour concrete for footings and slab.