Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 07/31/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
Add supports for gas line throughout. Secure gas line throughout. Replace fresh air intake. Elevate fresh air duct of ceiling. Add blocking to fresh air and 1st bedroom. Move smokie 3' from bathroom. Move smokie 6" away from wall in master bedroom. Pex lines need to be 12" away from any can lights. Add nail plates to electrical lines that are less than an 1"1/4. 7/31/2024 |
| 08/01/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
8/1/2024 corrections were made. |