Date Description Inspector Results Comments
06/27/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing hangers at entry. Add 2x to transfer load from second floor. Missing nailing at bottom plate perimeter at 2nd floor. Missing straps from beams to studs. Add anchor bolts at shear wall in great room. 6/27/2024
06/28/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 6/28/2024