Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0124-00007
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/30/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing hanger at stair way. Loose shear way at second floor. Provide anchor bolts per shear wall schedule. Missing h25 clip at bedroom north wall. Check perimeter nailing. Interior at foyer wall and nails. 7/30/2024 | |
08/08/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections were made. 8/8/2024 |