Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0124-00006
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/16/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing anchor bolts back side of house, missing rsp4 clips left side of house, load from second floor Girder Trusses must transfer continuously down to first floor. Add blocking between floors at both sides of house to allow continuous transfer of load., missing anchor bolt at front door entrance, nail rsp4 clip at back side of house. | |
05/02/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing anchor bolt at front door entrance, loose anchor bolt at front door entrance, still missing rsp4 clips, STOPPED INSPECTION. View previous notes. | |
05/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |