Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/21/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 1-21-25, nail down masa clip to mudsill south side of garage, shear walls not per approved plans-add nails throughout for over penetrated nailing/spacing along edges, add nails to roof at marked locations, and shot pins at interior framing. | |
| 01/23/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | ||
| 01/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 1/25/25 Pass. |