Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Sister 2x6 underneath header at entry and add x2 2x6's underneath header. Add anchor bolts at shear walls. Add rsp clips at south end wall of home. Finish nailing off cs16' s straps and STHD. RFI on hold down in front entry that missed studs. Loose shear walls. Add gable end truss exceeding 6'. Verify x3 2x4's underneath header at garage entry. 8/27/2024
09/06/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Corrections were made. 9/6/2024