Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0124-00001

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Roof Nailing  Re-inspection required Sister 2x6 underneath header at entry and add x2 2x6's underneath header. Add anchor bolts at shear walls. Add rsp clips at south end wall of home. Finish nailing off cs16' s straps and STHD. RFI on hold down in front entry that missed studs. Loose shear walls. Add gable end truss exceeding 6'. Verify x3 2x4's underneath header at garage entry. 8/27/2024
09/06/2024 COT - RSBU - Roof Nailing  Passed Corrections were made. 9/6/2024