Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0124-00001
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Sister 2x6 underneath header at entry and add x2 2x6's underneath header. Add anchor bolts at shear walls. Add rsp clips at south end wall of home. Finish nailing off cs16' s straps and STHD. RFI on hold down in front entry that missed studs. Loose shear walls. Add gable end truss exceeding 6'. Verify x3 2x4's underneath header at garage entry. 8/27/2024 | |
09/06/2024 | COT - RSBU - Roof Nailing | Passed | Corrections were made. 9/6/2024 |