Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
04/17/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Not ready.
04/18/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 4/18/23 apex too close to can light. Support duct work off recessed cans. Duct work not attached to register. Register not blocked on 3 sides. Electrical optional ceiling fan and light needs 14/3 wire. STOPPED INSPECTION.
04/20/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Not ready.
4/18/23 apex too close to can light. Support duct work off recessed cans. Duct work not attached to register. Register not blocked on 3 sides. Electrical optional ceiling fan and light needs 14/3 wire. STOPPED INSPECTION.
4/20/23: 4 over-notched bearing wall studs (let-ins), water test shower pan, line set not connected, install anchor bolts within 12" of end of all shear walls.
04/25/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed