Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
01/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed House has proceeded to intermediate without passing exterior clips and sheathing. Continuing will be at risk.
10/26/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Add nails to h2.5 clip to right side of garage, missing second trimmer at each side of back porch entrance, add nails to rsp4 clip to right of front porch, missing anchor bolts at back shear wall and perimeter of house.