Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
11/14/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Anchor bolts loose. Tighten all anchor bolts throughout., add nails to hanger at family room, girder truss at kitchen missing 2 2x6 studs and 2 2x4 studs for bearing, missing second balloon framed king stud right side of window by front door, missing rat runs at trusses.
11/14/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Anchor bolts loose. Tighten all anchor bolts throughout., add nails to hanger at family room, girder truss at kitchen missing 2 2x6 studs and 2 2x4 studs for bearing, missing second balloon framed king stud right side of window by front door, missing rat runs at trusses.
11/16/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
11/16/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed