Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0123-00263
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Duct register at powder room not blocked, add nail plate to top plate of condensate line at kitchen, missing nail plates in first floor, missing nail plates second floor throughout, over notched studs. Add stud shoe to middle notched stud at master bathroom, block duct registers on 3 sides, plumbing not per plans. Make proper corrections according to plans or revise plans showing current layout of plumbing work done and provide updated city stamped plans at Final. | |
02/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Duct register at powder room not blocked, add nail plate to top plate of condensate line at kitchen, missing nail plates in first floor, missing nail plates second floor throughout, over notched studs. Add stud shoe to middle notched stud at master bathroom, block duct registers on 3 sides, plumbing not per plans. Make proper corrections according to plans or revise plans showing current layout of plumbing work done and provide updated city stamped plans at Final. | |
03/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
03/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |