Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0123-00257
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
RSBU - Building Final | Re-inspection required | 8/23/24: insulation required to be UV coat at hose bib and water heater, roof not complete, post tension tag required at hose bib, properly secure electrical whip at water heater, knock out at panel needs to be sealed, panel schedule not complete, cut clean out to grade, thermostat must be dropped to 54" o.c above floor, garage door must be self closing and rated 20 min door, no attic access, tempered glass required at shower, smoke alarm missing in bedroom upstairs. | ||
08/27/2024 | RSBU - Building Final | Passed | Corrections have been made. 8/27/2024 |