Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0123-00253
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/01/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 9/1/23: nailing at upstairs shear wall not per schedule, HTT4 at shear wall do not substitute for Anchor bolt (missing anchor bolts at shear walls 12" from edge) | |
11/06/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |