Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0123-00251
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/07/2023 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | 7/7/23: clean footings at ufer and by garage, Rebar must have 3" clearance from earth. Footing to left side of kitchen missing rebar reinforcement. | |
07/10/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 7-10-23: Ufer ground is in place and tied to the rebar reinforcement. Monolithic footings are properly dug with rebar reinforcement in place. Post tension cabling is installed per plans. Subsoil is compacted and ready for concrete pour. |