Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 04/21/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
4/21/23- missing Anchor Bolts in garage @ front porch, missing hold down on 2x6 exterior garage, need engineer fix for blow out pedestal at rear porch, h25 clips on center bearing wall, too many shiners at roof above stairwell. |
| 06/14/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|
| 07/10/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Passed on 6/14/23 by Robert |