Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Progress
Permit Number - TC-MDP-0123-00236
Inspection Description - RSBU - Building Progress
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2024 | RSBU - Building Progress | Re-inspection required | Secure gas lines ceiling throughout house VTR in master bath not secured Nail plates master bath shower lines missing bored too close to edge Fire foam dead spots and penetrations Tub not under test Water lines not under test Fresh air within 10ft min from vtr in bath. |
|
03/06/2024 | RSBU - Building Progress | Passed |