Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141434700

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Gas Pressure Test 

Permit Number - TC-MDP-0123-00205

Inspection Description - COT - RSPL - Gas Pressure Test 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
04/11/2024 COT - RSPL - Gas Pressure Test  Re-inspection required Pex lines must be 18” away from next soldered joint at water hose and water heater appliances per M2105.10.2., gas not under test, plumbing not per plans. Missing cleanouts throughout, add nail plates to kitchen sink drains and at sole plate right side of range behind 3” pipe, shower pan not under test, dwv not under test. Potential leak at next gen suite.Stopped inspection. More items may be added.
04/12/2024 COT - RSPL - Gas Pressure Test  Passed