Parcel: 141434750

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0123-00204

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/05/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Back porch entrance missing trimmer stud on each side, missing kind stud at window between garage and in-law suite entrance.
01/10/2024 COT - RSBU - Exterior Clips/Sheathing  Passed
12/20/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Back porch entrance missing trimmer stud on each side, loose anchor bolts. Tighten/torque anchor bolts to spec. throughout, missing kind stud at window between garage and in-law suite entrance, add full 2x4 stud running continuous top to bottom plates to left side of 4x8 column by stairs, missing 4x8 column in second floor left side of house to fully bear load of GT, missing CS16 straps back of house, last mechanical truss B03 missing lateral bracing, staircase handrails not installed.