Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0123-00204
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Back porch entrance missing trimmer stud on each side, missing kind stud at window between garage and in-law suite entrance. | |
01/10/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
12/20/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Back porch entrance missing trimmer stud on each side, loose anchor bolts. Tighten/torque anchor bolts to spec. throughout, missing kind stud at window between garage and in-law suite entrance, add full 2x4 stud running continuous top to bottom plates to left side of 4x8 column by stairs, missing 4x8 column in second floor left side of house to fully bear load of GT, missing CS16 straps back of house, last mechanical truss B03 missing lateral bracing, staircase handrails not installed. |