Inspection Status: Re-inspection required
Inspection History: COT - LCEL - Electrical Intermediate
| Date |
Description |
Inspector |
Results |
Comments |
| 05/08/2026 |
COT - LCEL - Electrical Intermediate |
|
Re-inspection required |
5-8-26: missing plastic bushings at disconnect box, label all junction boxes above ceiling and at in wall. Provide an updated RFI showing tap box/electrical wall mount at existing dishwashing area. Above ceiling electrical not ready-all junction boxes must be labeled, Mc cabling must be secured and off the ceiling grid, seal open knockouts and provide plastic bushings where awg wires penetrate metal boxes. |
| 05/11/2026 |
COT - LCEL - Electrical Intermediate |
|
Passed |
Passed 5/11/26 |