Inspection Status: Re-inspection required
Inspection History: COT - LCEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/18/2026 |
COT - LCEL - Electrical Final |
|
Re-inspection required |
8-18-26: missing receptacle cover above ceiling at bedroom 6, seal water closet, ADA shower grab bars not per plans, missing shower seat, front grab bar and side grab bar is installed incorrectly-see plans for details, grab bar behind water closet must be 36" in length and must be installed 36" aff, lower lavatory to 34" aff, and mirror to 40" to the reflective surface, add insulation to hot copper lines verified at water heater, seal condensate penetration at water heater closet, paint exterior plastics, threshold at front entrance does not meet ADA required-threshold must be beveled, missing carbon monoxide detectors throughout. |
| 09/04/2026 |
COT - LCEL - Electrical Final |
|
Passed |
9-4-26: electrical final approved. |