Inspection History Details
Inspection Status: Requested
Inspection History: COT - LCBU - Building Final
Permit Number - TC-COM-1124-02231
Inspection Description - COT - LCBU - Building Final
Inspection Status - Requested
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - LCBU - Building Final | Requested | |||
| 01/09/2026 | COT - LCBU - Building Final | Re-inspection required | Inspector Findings – 01/09/2026 Exterior receptacles do not have required approved weatherproof covers. Junction box covers are missing at the fire riser. Air gap is required at the fire riser. ADA receptacle requirements are not met. Circuit B-82 has no power. Water heater manufacturer’s required side clearance is not met. All disconnect boxes are not labeled. Roof receptacle has no power. All rooftop equipment must be labeled, and proper amperage must be verified for all equipment. Insulation at the ice maker is not properly protected. Kitchen equipment is not properly secured to the wall. Circuit B-27 is off at the seating area. NOTE: on the panels that were penetrated via screws, one of the following options is required.1) a UL inspection by the manufacturer is required and the inspection report would have to submitted to the for city for review 2) a letter by the UL manufacturer documenting the panels are safe to use and there is no possibility of arching 3) replace panels. Conditions for Occupancy: Engineering final inspection must be approved prior to issuance of Certificate of Occupancy (CofO). Water sterilization is required prior to issuance of Temporary Certificate of Occupancy (TCO) above Level 1. Pima County Health Department inspection must be approved prior to issuance of TCO above Level 2. |
|
| 07/14/2025 | COT - LCBU - Building Final | Partial Pass | This inspection is for wall footings and interior column footings. Requested PDSD add an excavation/rebar inspection to this permit. | |
| 08/07/2025 | COT - LCBU - Building Final | Partial Pass | 8-7-25: reinforcement verified per foundation plan-Okay for concrete placement. | |
| 08/11/2025 | COT - LCBU - Building Final | Partial Pass | Partial pass. Total of 6 spread footers for canopy. Detail F11 page F2FC2. Okay for concrete placement. 8/11/2025 | |
| 08/29/2025 | COT - LCBU - Building Final | Re-inspection required | 8-29-25: framing inspection-missing anchor bolts, bolts & washers throughout together with hold downs. Missing A-34's per detail S301/D3, sheathing nailing not per schedule-nailing cannot be closure than 3/8" from edges/joints and cannot over-penetrate more /16". Note: stopped inspection-additional items may be added. Reschedule inspection when ready. |
|
| 09/05/2025 | COT - LCBU - Building Final | Partial Pass | 9-5-25: hold-downs/anchor bolts, nailing at exterior clips/sheathing at shear walls verified per plans. Roof & parapet nailing also inspected & approved-Okay to dry-in roof/parapets and install double exterior walls. | |
| 09/09/2025 | COT - LCBU - Building Final | Partial Pass | 9-9-25: extended pararpet on high walls (north, south, east & west side) verified per detail S601/A3. Okay to install 5/8" wood deck at progress areas-call for a nailing inspection when ready. | |
| 09/17/2025 | COT - LCBU - Building Final | Partial Pass | This inspection is for densglas nailing for cooking hood area and walk - in cooler areas. | |
| 10/03/2025 | COT - LCBU - Building Final | Partial Pass | 10-3-25: in wall DWV/domestic verified under test at back house areas. In wall electrical at same areas verified per plans, however, add Boca plates where blocking was over notched & firefoam all penetrations. Areas of focus include, back interior south wall & several areas throughout back house located on east & central walls. Inspection required for mentioned areas. | |
| 10/09/2025 | COT - LCBU - Building Final | Re-inspection required | 10/9/25: re-inspection required for shearwall. | |
| 10/10/2025 | COT - LCBU - Building Final | Partial Pass | 10-10-25: shear wall nailing at dining, queue, meal fulfillment area, ready vest, storage, it closet, office, kitchen, service area, eq room verified per plans and approved. Okay to continue with construction at progress areas. NOTE: on the panels that were penetrated via screws, one of the following options is required.1) a UL inspection by the manufacturer is required and the inspection report would have to submitted to the for city for review 2) a letter by the UL manufacturer documenting the panels are safe to use and there is no possibility of arching 3) replace panels. |
|
| 10/30/2025 | COT - LCBU - Building Final | Canceled | Contractor canceled: information only. | |
| 12/29/2025 | COT - LCBU - Building Final | Not Ready |