Inspection Status: Partial Pass
Inspection History: COT - HCEL - Electrical Intermediate
Permit Number - TC-COM-1124-02153
Inspection Description - COT - HCEL - Electrical Intermediate
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Partial pass. Rough in electrical in walls. 6th floor 24 units east end for guest rooms pending puddy pack on all receptacles at party walls within 2’ from each other. 6/11/2025 | |
| 06/17/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Level #3; Northeast portion room units of current work phase. In wall electric in room units. Ok to patch and tape progress areas. | |
| 06/23/2025 | COT - HCEL - Electrical Intermediate | Re-inspection required | Partial pass. Rough in electrical in walls. 6th floor 24 units east end for guest rooms pending puddy pack on all receptacles at party walls within 2’ from each other. 6/11/2025 6/23/25: 6725-6748, 6742 not ready, 6746 not ready, 6743 not ready, 6750 not ready, 6741 not ready, 6739 not ready, supports on pex lines required throughout top track and vertical/horizontal runs, incomplete rough-ins throughout. Full walk through required on next inspection. Copper hangers must be coated or taped off. Putty packs required at bathroom receptacle that are in back to back cell within 24" seal penetrations in floor. |
|
| 06/24/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 6/24/25:plumbing and electrical in rooms 6728,6730,6732,6734,6736,6738,6740,6742,6744,6746,6748. Electrical in walls in rooms 5726,5728,5730,5732,5734,5736,5738,5740,5742,5746,5748,5750, |
|
| 06/25/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Partial pass. Rough in electrical in walls. 6th floor 24 units east end for guest rooms pending puddy pack on all receptacles at party walls within 2’ from each other. 6/11/2025 6/23/25: 6725-6748, 6742 not ready, 6746 not ready, 6743 not ready, 6750 not ready, 6741 not ready, 6739 not ready, supports on pex lines required throughout top track and vertical/horizontal runs, incomplete rough-ins throughout. Full walk through required on next inspection. Copper hangers must be coated or taped off. Putty packs required at bathroom receptacle that are in back to back cell within 24" seal penetrations in floor. 6/24/25:plumbing and electrical in rooms 6728,6730,6732,6734,6736,6738,6740,6742,6744,6746,6748. Electrical in walls in rooms 5726,5728,5730,5732,5734,5736,5738,5740,5742,5746,5748,5750, 6/25/25: electrical intermediate at 6th floor restrooms completed, electrical intermediate at 5th floor rooms completed pending restrooms. |
|
| 06/30/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Partial pass. Rough in electrical in walls. 6th floor 24 units east end for guest rooms pending puddy pack on all receptacles at party walls within 2’ from each other. 6/11/2025 6/23/25: 6725-6748, 6742 not ready, 6746 not ready, 6743 not ready, 6750 not ready, 6741 not ready, 6739 not ready, supports on pex lines required throughout top track and vertical/horizontal runs, incomplete rough-ins throughout. Full walk through required on next inspection. Copper hangers must be coated or taped off. Putty packs required at bathroom receptacle that are in back to back cell within 24" seal penetrations in floor. 6/24/25:plumbing and electrical in rooms 6728,6730,6732,6734,6736,6738,6740,6742,6744,6746,6748. Electrical in walls in rooms 5726,5728,5730,5732,5734,5736,5738,5740,5742,5746,5748,5750, 6/25/25: electrical intermediate at 6th floor restrooms completed, electrical intermediate at 5th floor rooms completed pending restrooms. 6/30/25: electrical intermediate in bathroom approved 5th floor east end ok to proceed, |
|
| 07/15/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 7/17/25: Electrical intermediate approved in units (4725,4726,4727,4728,4729,4730,4731,4732,4733,4734,4735,4736,4737,4738,4739,4740,4741,4742,4743,4744,4745,4746,4747,4748 | |
| 08/08/2025 | COT - HCEL - Electrical Intermediate | Not Ready | 8-8-25: not ready. Contractor will reschedule. | |
| 08/14/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 8/14/25: electrical intermediate in units approved in units 7233,7231,7229,7227,7225,7223,7221,7219,7217,7218,7220, 7222,7224,7226,7228,7230,7232,7234. Pending bathrooms. | |
| 08/19/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 8/19/25: electrical in wall in rooms 6233,6231,6229,6227,6225,6223,6221,6219,6216,6215,6217,6218,6220, 6222,6224,6226,6228,6230,6232,6234, 6113,6111,6109, 6110,6112,6114. Pending bathrooms |
|
| 08/26/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Building #2; Level #5, rooms 5215,- 5234: Building #1, Level #5, rooms 5105, 5106, 5105 - 5114: all rooms listed are for sleeping,area in wall electric. | |
| 09/08/2025 | COT - HCEL - Electrical Intermediate | Not Ready | ||
| 10/14/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 10-14-25: in wall electrical & above ceiling lighting in room's 5101, 6106, 6107, 4101 verified per plans. Okay to continue with construction at progress areas. Note: place all exposed alarm wiring in a junction box. |
|
| 10/24/2025 | COT - HCEL - Electrical Intermediate | Re-inspection required | 10-24-25: in wall electrical for room's 3233, 3231-add clamp to stud within 12" stemming out of box, 3229-puddy pack on receptacles adjacent rooms within 2' of each other, 3227-puddy pack, 3231-puddy pack, 2333-puddly pack , 3221-add clamp,at bathroom Mac cable, 3223, 3219, 3217, 3215, 3216-puffy pack required at bathroom, 3218 putty pack at bathroom & receptacle on bedroom side, 3220-clamp at bathroom receptacle within 12" stemming out of box, 3222-puddy pack between receptacles at bathroom/bedroom, 3113, 3111-add clamps to McCable within 12" stemming out of box at bathroom, and 3109-clamp required at bathroom receptacle, 3107, 3105, 3103, 3101-not ready, 3100-puddy pack between bathroom/bedroom wall and puddy pack between receptacles at adjacent rooms, 3102-puddy pack. | |
| 10/27/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 10-27-25: reinspection for in wall electrical intermediates for room's 3223, 3231, 3229, 3227, 3225, 3221, 3216, 3111, 3109, 3100 approved- okay to continue with construction at progress areas. Room 3102-not ready, | |
| 11/12/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 11/12/2025 2nd floor approved. Okay to proceed progress areas. | |
| 11/17/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | Building #2; Room units #2101, 1215 - 1225. Electric in wall in bathrooms, OK to cover progress areas. | |
| 11/28/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 11/28/2025 partial pass. 7th floor building 5 in walls at both bathrooms and sleeping areas approved. Okay to proceed progress areas. | |
| 12/03/2025 | COT - HCEL - Electrical Intermediate | Partial Pass | 12/3/2025 partial pass. Bathroom only 7th floor approved. Okay to proceed progress areas. | |
| COT - HCEL - Electrical Intermediate | Scheduled |