Inspection Status: Re-inspection required
Inspection History: COT - HCME - Mechanical Progress
| Date |
Description |
Inspector |
Results |
Comments |
| 09/11/2024 |
COT - HCME - Mechanical Progress |
|
Re-inspection required |
9/11/24: copper plumbing in restroom running against sheet metal studs needs to be protected. All top plate penetrations need to be fire foamed. Fur out walls need to be blocked every 10 feet. Registers must be blocked on three sides. Pex going through block wall must have protective sleeve. Stopped inspection |
| 09/19/2024 |
COT - HCME - Mechanical Progress |
|
Partial Pass |
see Plumbing Intermediate Notes. |
| 09/30/2024 |
COT - HCME - Mechanical Progress |
|
Passed |
|