Permit: TC-COM-1122-00147

Parcel: 12511016A


Addresses:

3537 E 4TH ST

Inspection Status: Not Ready

Inspection History: COT - HCPL - Plumbing Intermediate 

Date Description Inspector Results Comments
09/05/2024 COT - HCPL - Plumbing Intermediate  Not Ready work incomplete
09/11/2024 COT - HCPL - Plumbing Intermediate  Re-inspection required 9/11/24: copper plumbing in restroom running against sheet metal studs needs to be protected. All top plate penetrations need to be fire foamed. Fur out walls need to be blocked every 10 feet. Registers must be blocked on three sides. Pex going through block wall must have protective sleeve. Stopped inspection
09/19/2024 COT - HCPL - Plumbing Intermediate  Re-inspection required (with fee) 1-Fur out walls need to be blocked every 10 feet.
2-copper plumbing in restroom running against sheet metal studs needs to be protected.
3-Complete electrical rough-in.
4- Block below beam saddle is split and displacing; provide fix from EOR.
COT - HCPL - Plumbing Intermediate  Re-inspection required 9/30/24: copper pipe touching metal stud needs to be protected.
10/04/2024 COT - HCPL - Plumbing Intermediate  Passed