Permit: TC-COM-1122-00147

Parcel: 12511016A


Addresses:

3537 E 4TH ST

Inspection Status: Re-inspection required

Inspection History: COT - HCME - Mechanical Intermediate

Date Description Inspector Results Comments
09/11/2024 COT - HCME - Mechanical Intermediate Re-inspection required 9/11/24: copper plumbing in restroom running against sheet metal studs needs to be protected. All top plate penetrations need to be fire foamed. Fur out walls need to be blocked every 10 feet. Registers must be blocked on three sides. Pex going through block wall must have protective sleeve. Stopped inspection
COT - HCME - Mechanical Intermediate Passed