Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 11811015Q


Addresses:

775 W SILVERLAKE RD


Inspection Status: Not Ready

Inspection History: COT - HCBU - Excavation/Rebar/Zoning 

Permit Number - TC-COM-1122-00082

Inspection Description - COT - HCBU - Excavation/Rebar/Zoning 

Inspection Status - Not Ready

Date Description Inspector Results Comments
04/25/2023 COT - HCBU - Excavation/Rebar/Zoning  Not Ready
04/27/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass Column line C8. Okay for concrete placement in 4 (7B) footings. Rebar per plans. 4/27/2023
05/03/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass column line c8/ca and cf
column pedi stall , c8/cc,cb,cc,cd,ce
05/08/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass Column footings at GL: C.9/A - F (6 each footings). Ok to place concrete in progress areas.
05/11/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass Column lines C8 - CA and CFand C9 - CA, CB, CC, CD,CE and CF. Okay for concrete placement in columns. 5/11/2023
05/16/2023 COT - HCBU - Excavation/Rebar/Zoning  Canceled Canceled. Inspection is due to backfill, compaction for driveway expansion and new curb. 5/16/2023
08/10/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass CH line C7- C5. CG line C7 - C4 per plan okay for concrete placement in footings 8/10/2023
08/11/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass CH line C1 - C4. CG line C1 - C3 rebar per plan okay for concrete placement in footings. 8/11/2023
08/15/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass CH line C4 - C7 per plan okay for concrete placement in pedestals. CG line C4 -C7 rebar per plan okay for concrete placement in pedestal 8/15/2023
08/17/2023 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass Column line C8. Okay for concrete placement in 4 (7B) footings. Rebar per plans. 4/27/2023

Column lines C8 - CA and CFand C9 - CA, CB, CC, CD,CE and CF. Okay for concrete placement in columns. 5/11/2023

Canceled. Inspection is due to backfill, compaction for driveway expansion and new curb. 5/16/2023

CH line C7- C5. CG line C7 - C4 per plan okay for concrete placement in footings 8/10/2023

CH line C1 - C4. CG line C1 - C3 rebar per plan okay for concrete placement in footings. 8/11/2023

CH line C4 - C7 per plan okay for concrete placement in pedestals. CG line C4 -C7 rebar per plan okay for concrete placement in pedestal 8/15/2023

8/17/23: CH line C1-C3 per plan okay for concrete placement in pedestals. CG line C1-C3 per plan okay for concrete placement in pedestals.
11/09/2023 COT - HCBU - Excavation/Rebar/Zoning  Passed