Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - HCPL - Plumbing Intermediate
Permit Number - TC-COM-1024-02001
Inspection Description - COT - HCPL - Plumbing Intermediate
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2025 | COT - HCPL - Plumbing Intermediate | Re-inspection required | 8-8-25: in wall plumbing -firefoam all penetrations, secure pex and DWV with straps above all blocking. | |
| 08/12/2025 | COT - HCPL - Plumbing Intermediate | Re-inspection required | 8-12-25: secure DWV at west wall every 4', firefoam DWV penetrations at west side and firefoam horizontal penetration at south wall where metal conduit and DWV penetrates wall-all penetrations from an unconditioned space to a conditioned space require firefoam, add Boca plate and strap to DWV at electrical room, extend DWV through roof at electrical room and firefoam penetrations. | |
| 08/13/2025 | COT - HCPL - Plumbing Intermediate | Partial Pass | 8-13-25: plumbing corrections made at interior side of building. Okay to continue with construction. | |
| 11/14/2025 | COT - HCPL - Plumbing Intermediate | Passed | 11-14-25: approved. |