Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-COM-0925-01698

Parcel: 11705056B


Addresses:

440 N 7TH AV

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Masonry Pregrout 

Date Description Inspector Results Comments
06/12/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass. 1st lift For elevator hoistway walls. Okay to grout progress areas. 6/12/2026
06/16/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass, 2nd lift Elevator hoistway pre grout at 8ft w knockouts in tower approved. 6/16/2026
06/17/2026 COT - HCBU - Masonry Pregrout  Canceled Canceled per contractor. 6/17/2026
06/18/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass 3rd lift Next 8 foot lift. About 40% past 2nd floor elevation.
Includes:
Horizontal double bond beam at elevator door opening on south wall
Vertical and north, east, and south returns (corners only return 8”)
Knock outs 8’ below last course installed (above last pre grout inspection line). Okay to grout progress areas. 6/18/2026
06/23/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass. 4th lift Next 8’ lift w knockouts on elevator hoistway. 1’ into 3rd floor reinforcements approved. Okay to grout progress areas. 6/23/2026
06/25/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass. 5th lift next 8' lift w knockouts on elevator hoist way. Reinforcements approved. Okay to grout progress areas. 6/25/2026
06/29/2026 COT - HCBU - Masonry Pregrout  Partial Pass Partial pass. 6th lift next 8' lift w knockouts on elevator hoist way. Reinforcements approved. Okay to grout progress areas. 6/29/2026