Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - LCPL - Plumbing Intermediate
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2026 | COT - LCPL - Plumbing Intermediate | Partial Pass | 2/13/26: plumbing underground approved. Ok to proceed with backfill | |
| 10/30/2026 | COT - LCPL - Plumbing Intermediate | Not Ready | ||
| 11/20/2026 | COT - LCPL - Plumbing Intermediate | Not Ready | 1-Missing nail plates in multiple locations. 2-Missing drinking fountain. 3-Venting is not per plan. 4-Iron column has been removed from center of bearing floor beam. 5-Wall has been built to support floor trusses that are not designed for bearing at location of support wall. 6-No foundation plan is included with approved plans to verify a footing under support wall. |