Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-COM-0923-02206

Parcel: 11611011A


Addresses:

280 N CARAPAN AV

Inspection Status: Partial Pass

Inspection History: COT - LCBU - Framing

Date Description Inspector Results Comments
01/22/2024 COT - LCBU - Framing Partial Pass Partial pass. All ledgers, joist, beams, post, and wall studs per plan and matching details. (East end of buildings #2 and #3) (1st floor to 3rd floor) okay to proceed progress areas. 1/22/2024
04/30/2024 COT - LCBU - Framing Canceled
05/02/2024 COT - LCBU - Framing Re-inspection required West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024
05/07/2024 COT - LCBU - Framing Partial Pass 1/22/2024

West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024

5/7/24: corrections made on west end of apartments for buildings #2 and #3.
07/30/2024 COT - LCBU - Framing Re-inspection required Partial pass. All ledgers, joist, beams, post, and wall studs per plan and matching details. (East end of buildings #2 and #3) (1st floor to 3rd floor) okay to proceed progress areas. 1/22/2024

West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024

5/7/24: corrections made on west end of apartments for buildings #2 and #3.
7/30/24: Scuppers missing throughout
08/05/2024 COT - LCBU - Framing Passed