Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Building Final 

Date Description Inspector Results Comments
01/07/2025 COT - LCBU - Building Final  Re-inspection required 1/7/24: kitchen counter top receptacles must be GFCI, anti-tip required at range, cover plate for range outlet must be installed, GFCI required for garbage disposal, water hammer arrestor required at dishwasher, kitchen sink faucet is leaking, dishwasher high loop must be supported, smoke detectors must be installed in bedrooms on new Arc fault protected circuit, panel schedule at sub-panel must be updated once new circuit is added for smoke detectors.
01/24/2025 COT - LCBU - Building Final  Passed 1-24-25, building final approved.