Inspection Status: Re-inspection required

Inspection History: COT - HCPL - Plumbing Intermediate 

Date Description Inspector Results Comments
04/02/2025 COT - HCPL - Plumbing Intermediate  Re-inspection required 4-2-25, verified DWV under test, however, spacers are required where any copper is making contact with metals. Firefoam any penetrations at top plates. Add spacers throughout, and reschedule when ready.
04/04/2025 COT - HCPL - Plumbing Intermediate  Re-inspection required 4-2-25, verified DWV under test, however, spacers are required where any copper is making contact with metals. Firefoam any penetrations at top plates. Add spacers throughout, and reschedule when ready.
4/4/25: plastic Grommets required where copper piping is penetrating through metallic studs. Insulation has been installed in walls. Please remove insulation from walls in order to conduct inspection.
04/08/2025 COT - HCPL - Plumbing Intermediate  Passed 4-8-25, grommets installed throughout, DWV secured & firefoam added at penetrations. Plumbing intermediate inspection approved.